P6021A AC Current Probes Datasheet
The P6021 and P6022 Current Probes provide versatile AC current measurements. Both probes provide accurate current measurements over a wide range of frequencies. The P6021 and P6022 allow current measurements without breaking the circuit by clipping onto the current carrying conductor. Shielded probe heads are not grounded when the slides are in their open positions, eliminating accidental grounding of the circuit under test.
KEY PERFORMANCE SPECIFICATIONS
P6021A
120 Hz to 60 MHz
10.6 A RMS, 250 A peak, 10 mA sensitivity
P6022
935 Hz to 120 MHz
4 A RMS, 100 A peak, 1 mA sensitivity
KEY FEATURES
For 1 MΩ inputs
Shielded probe head
AC only
Split core construction allows easy circuit connection
1.5 m (5 ft) cable
APPLICATIONS
Motor drives
Power invertersconverters
Power supplies
Avionics
P6021A
For general purpose applications, the P6021A provides wide-band performance with excellent low-frequency characteristics. Bandwidth is 120 Hz to 60 MHz. The probe range is switchable between 2 mAmV and 10 mAmV.
P6022
With a head size of 0.47 in. x 0.25 in. (10 mm x 6 mm, about half the size of the P6021A) and a bandwidth of 935 Hz to 120 MHz, the P6022 is ideal for measuring currents in compact, high-performance circuits. Passive termination output is switchable between 1 mAmV and 10 mAmV.